Pumping concrete line pressure and equipment choice Related Information

SPECIFICATIONS AND STANDARD DRAWINGS

3. Pump and pressure main sizing including system curves for initial pump installation and ultimate size pumps. Minimum pressure main size is four (4) inch diameter. Minimum velocity at design pump rate is 2 feet per second. 4. Uplift or buoyancy potential of wet well. The minimum factor of safety is 2.0. C. Catalog cut sheets 1. Structures. 2.

High Pressure Line Pumps - Specialised Concrete Pumping

High pressure and output to meet today's high demand job sites. On today's complex building sites, concrete needs to be pumped further, higher and faster than ever before and a high-pressure line pump is the right solution when it comes to pumping in extreme conditions.

Proper Sizing of Lines and Equipment of Concrete Pump

Used Concrete Pumps, Trucks, Trailer for Sale - Concrete

Surge Control in Pumping Stations | Pumps & Systems

Dec 17, 2011 · by Pumps & Systems. 12/17/2011. This primer presents basic surge control principles and the functions of various valves associated with pumping stations. Water pipelines and distribution systems are subjected to surges almost daily, which over time can cause damage to equipment …

Concrete Pump Operator Resume Examples | JobHero

Concrete Pump Operator Resume Examples. Concrete Pump Operators use pumps to pour ready-mix concrete on construction sites. Typical duties for this job include maintaining tools, driving trucks, assembling concrete pumps, and collaborating with other workers. Based on our collection of resume samples, these workers need to demonstrate stamina

Concrete Pumps - Types and Selection - The Constructor

The concrete pumping to different heights like in the construction of high-rise building can be performed by boom concrete pumps. Boom concrete pumps allow the pipeline to reach along, upwards and below. Hence tight spots can be cast by these pumps. Obstacles during the concrete casting path can be easily overcome by such pumps. 2. Line

6 Basic Rules of Pump Piping - Crane Engineering

Include a straight run pipe length equal to 5 to 10 times the pipe diameter between the pump inlet and any obstruction in the suction line. Note: Obstructions include valves, elbows, "tees", and etc. Keeping the pump suction piping short ensures that the inlet pressure drop is as low as possible.

Concrete Pumps | What is a concrete pump?

A Static Concrete Pump, also referred to as a Stationary, Line Pump or Trailer Mounted Concrete Pump is mounted on a trailer and requires a separate pipeline to be attached reaching to wherever the concrete needs to be placed. The pipeline is a series of steel or rubber pipes, known also as concrete placing hoses, linked together and manually

Major Problems in Concrete Pumping Works: How to Avoid

The major problems that one encounters when pumping concrete are blockage of pipeline, and segregation and bleeding of concrete mix. Blockage is the failure of concrete to emerge at the end of the pipeline. It is characterized by an increase in pressure that can be observed on the pressure gauge. Blockage can be caused by improper selection of

Concrete Trailer | Line Pumps For Sale

Trailer pumps can pump up to 2,000ft. vertically and up to 8,000ft. horizontally. They are extremely versatile and can pump concrete almost anywhere for high-rise structures, underground tunnels and shafts and even underwater for marine construction.

Equipment | Jensen's Concrete Line Pumping in Marietta

Concrete Pumping - How to Pump Cement - The Concrete Network

Why Pump Concrete? | Construction Equipment

Concrete Pumping - How to Pump Cement - The Concrete Network

Concrete Construction Article PDF - Pumping Concrete

Pumping. concrete: line pressure and equipment choice How to figure the best combination for smooth, efficient operation Figure 1. TAPPING INTO A LINE TO MEASURE PRESSURE. The service tee is filled to the top with oil before the plug is inserted. The pressure will be low if the line is straight,

Concrete Pump Blockage - Causes & Clearing - Concrete Network

A rise in line resistance, as shown on the pump pressure gauge, indicates line blockage. The first suspect spot for blockage is the reducer, which connects the concrete pump to the pipeline system. A quick build-up in pressure prior to the jam indicates the blockage is most likely in the pump area.

Pumping Concrete: Line Pressure and Equipment Choice

Line pressure requirements also depend on pipeline layout. The length of straight and horizontal pipeline, the vertical rise, the number and severity of bends, the amount of flexible hose used in the line—each has an effect on pressure needed to move the concrete. DIAMETER OF LINE. While a larger inside pipeline diameter cuts down on the pressure needed, it also has one enormous drawback: the larger the line, …

AMERICAN CONCRETE PUMPING ASSOCIATION

3B Line Pump - High Pressure 12 Months 4A Three-Section Boom 12 Months all the safeguards that should be incorporated in the construction and operation of concrete pumping equipment. The manufacturer of the equipment being operated should be contacted for specific

Pumps – Natal Pump Services

The external gear pump is the ultimate solution for high pressure pumping. Bearing support on both sides of the gears enables differential pressures to 500 PSI (34 BAR), or Intermittent to 2,500 PSI (170 BAR) Motor speed operation eliminates cost of speed reducer. Eliminates lubrication – no external axial or radial bearing required in most

Collection Systems Technology Fact Sheet: Sewers, Lift Station

in a pump room (dry pit or dry-well), that is easily accessible. The wet-well is a separate chamber attached or located adjacent to the dry-well (pump room) structure. Figures 1 and 2 illustrate the two types of pumps. Submersible lift stations do not have a separate pump room; the lift station …

Nationwide Concrete Pumping

Nationwide Concrete Pumping is one of Australia's largest Pumping Companies. With Branch Locations in Melbourne and Brisbane we are your safest choice when it concerns concrete pumping. With one of the largest fleets in Australia consisting of: 31+ Mobile Concrete Pumps ranging from 28m to 55m. 10 Mobile Line Pumps both Low & High Pressure.

Avoid too Much Pressure in Concrete | For Construction Pros

Jul 01, 2010 · Concrete placement technique directly affects placement rate. Placing concrete with a crane and bucket, as shown in the photo above, is a slower process than placing concrete with a pump …